Aluminum foil sealing machine common problems are the following points

by:NEWLINE     2020-08-15
Aluminum foil sealing filler 2019 - common problems are the following 04 - 01 09:09:28 aluminum foil sealing machine using the enterprise production operation has brought great convenience to us, it have higher working efficiency of everyone is obvious to all, but the machine will inevitably appear more or less problems, common problems are the following: failure problem a: if we filling in large size, feed chute is insufficient, lead to unstable liquid level. Built into filling is not allowed. The solution: can increase mending shoes or to close small ball valve, reset the filling time ( Lengthen the period of filling material) Slow filling speed to solve. Problem 2: if, after adjust the digital dial code or unit time doesn't change. Solution: when close to plug in the power supply. Problem 3: if there are any feed chute is enough, liquid level is stable, filling quantity inaccurate deficiency problems. The solution: may be debris jam filling channel. Check entry or manger in mouth filling material, the cleaning to clean can. Fault question 4: if you have closed stop filling liquid drip of later. Solution: 1, the filling material nozzle orifice may be damaged, reveal a mouth filling material finishing orifice, the diameter of the orifice is not greater than 7. 5mm。 Fixed aperture on the water sand paper after grinding flat spot face gently. 2, filling head ball valve damage, need to replace the ball valve. Problem five: if the touch switch after not fill material, time relay digital indicator LED flashing. Solution: it is possible that note material switch damage or loose time relay base, replace the same note material switch or press tight time relay base. Fault question 6: if the touch switch after not fill material, but the time relay digital LED lights flashing. Solution: 1, check the presence of air pressure or air pressure is too low, if do not conform to the requirements of the pressure, we should timely adjust, it is seen. 2, if the air pressure required, may be electromagnetic valve coil damage or pneumatic valve core was stolen card dead, can pull the power supply, open the plate, with a twisted or press the corresponding button beside a solenoid coil, such as valve can reverse action, it indicates that the damage of solenoid coil, if not the reversing, is the valve core is jammed, can replace solenoid coil or decomposed valve repair. As long as we pay attention to maintenance of the aluminum foil sealing filler at ordinary times, carefully observe the general common small problems we can solve the emergency response, before the factory after-sales maintenance people to further confirm this time, they will not become a hindrance we operating efficiency.
Custom message
Chat Online
Chat Online
Chat Online inputting...
Sign in with: