Matters needing attention during the operation of beverage machinery

by:NEWLINE     2021-05-01
Matters needing attention during the operation of the beverage machinery2018-08-30 17:16 Matters needing attention during the operation of the beverage machinery: 1. When the beverage machinery is in operation, pay attention to whether the equipment makes an abnormal sound. There is a need for maintenance, find out the cause and clear the fault. 2. It is strictly forbidden to stand on the equipment while the beverage equipment is running. 3. Check whether the UV lamp for cover disinfection is turned on, whether ozone is added to the cover of the cover bin, and whether the pure water pump for cover disinfection has a normal supply of water. 4. If the filling valve leaks, there are two possibilities: one is that the filling valve is opened and not reset, and the other is that the sealing ring of the filling valve is not well sealed. You can remove it for inspection and replace the sealing ring. 5. If there is a high cap or a crooked cap, there are the following situations: First, there is a problem with the fit of the cap and the bottle, and there may be a problem with one of them. The second is the torque of the cap screwing head is not enough, if you can screw it by hand, Then find out the capping head and increase the torque until it meets the requirements. Third, there is a problem with the bottle, mainly at the transition of the star wheel, it may be misaligned or loose, and it must be reset. 6. If the bottle is clamped by the bottle, there are the following situations: First, there is a problem with the bottle on the mouth of the air duct. Second, the spring of the bottle holder has lost its elasticity, or the bottle holder is loose or worn, and the bottle can no longer be clamped. Just replace it. 7. If the torque of the capping head has not been adjusted, replace the magnet, and then check the spring inside. If the elasticity is not enough, replace it. In addition, after the capping head cannot be returned, it must be removed for inspection. Replace parts. 8. If the cover is always blocked at the small star wheel of the cover slot, the position of the star wheel must be adjusted until it is smooth. If the outlet of the cap sorting machine is jammed, first check whether the component at the outlet is jammed, and blow the cover back Whether the air pressure is too high, then adjust its position or air pressure. 9. If the cover is not smooth, you can increase or decrease the spring pressure on the cover plate. In addition, check whether the excessive parts in contact with it are normal.
Custom message
Chat Online
Chat Online
Chat Online inputting...
Sign in with: